Table of Thermo King Alarms:

Green Thermo King AlarmYellow Thermo King AlarmRed Thermo King Alarm
It is a stored alarm. Indicates a condition that needs investigation but does not affect the unit’s operation. The alarm icon appears for 30 seconds when the unit is turned on and then disappears.Requires verification. This alarm is a warning to take corrective action before an abnormal condition becomes serious. The alarm icon will appear and remain on.Shutdown alarm indicating conditions that could damage the unit. The unit will shut down automatically, the alarm icon will appear, and the entire display will flash on and off.

Thermo King Alarms:

This table shows the alarm codes for Thermo King equipment, possible causes of the issue, and some measures to take.

  • Thermo King alarms are generated when the microprocessor detects an abnormal condition.
  • Multiple Thermo King alarms can occur simultaneously.
  • All generated alarms will be stored in memory until the operator clears them.
  • Document all alarm cases and communicate them to the service technician.
  • The Thermo King alarm table in Spanish shows all codes for all possible applications. Therefore, not all codes will be applicable to each individual unit.
  • The operator can repair certain faults, while others can only be repaired by the Thermo King dealer.
  • Some alarms may exist with Code 84.
  • The alarm may disappear automatically if the condition does not repeat.
  • Alarms that occur during a previous trip or a self-check of the unit will be preceded by a hyphen.
  • Some alarms are automatically self-eliminated when the operating condition that caused the alarm returns to normal.

Meaning of Thermo King Alarm Codes:

Alarm CodeEquipment Status Identification ColorOperator’s Action
Alarm Code 00Green = OK No alarmsNo action required.
Alarm Code 02Yellow Check the evaporator temperature sensor (zone)Check the temperature manually. Report the alarm at the end of the day.
Alarm Code 03Yellow Check (control) the return air temperature sensor (zone)Check the temperature manually. Report the alarm at the end of the day.
Alarm Code 04Yellow Check (control) the discharge air temperature sensor (zone)Check the temperature manually. Report the alarm at the end of the day.
Alarm Code 05Green = OK Check the ambient temperature sensorReport the alarm at the end of the day.
Alarm Code 06Green = OK Check the engine refrigerant temperature sensorReport the alarm at the end of the day.
Alarm Code 07Green = OK Check the engine revolutions or RPM sensorReport the alarm at the end of the day.
Alarm Code 08Yellow Unit operating with evaporator sensor (zone)Check the temperature manually. Report the alarm at the end of the day.
Alarm Code 09Yellow High evaporator temperature (zone)If the unit or zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
Alarm Code 10Red Take immediate action High compressor discharge pressure (or temperature)If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
Alarm Code 11Yellow Unit or zone control on alternative sensor (zone)Monitor the temperature manually. Report the alarm at the end of the day.
Alarm Code 12Red Take immediate action Sensor or digital input off (zone)The unit or zone cannot operate and is off. Repair immediately.
Alarm Code 13Yellow Sensor check (zone)Check the temperature manually. Report the alarm at the end of the day.
Alarm Code 14Green = OK Thawing completed by timeReport the alarm at the end of the day.
Alarm Code 15Yellow Check the glow plugs or the diesel engine air intake heater.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
Alarm Code 16Green = OK Manual start not completedReport the alarm at the end of the day.
Alarm Code 17Yellow Engine did not startIf the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
Alarm Code 18Yellow High temperature of the diesel engine coolant.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
Alarm Code 19Yellow Low oil pressure of the diesel engine.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
Alarm Code 20Yellow Engine (CR steam engine) did not startIf the unit or zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
Alarm Code 21Yellow Cooling cycle check (zone)Check the temperature manually. Report the alarm at the end of the day.

Table 1: Alarms 31-57

Alarm CodeStatusDescriptionAction
31YellowCheck the oil pressure switchIf the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
32RedTake immediate actionLow cooling capacity (zone)
33Green = OKCheck diesel engine RPMReport the alarm at the end of the day.
34YellowCheck modulation circuitCheck the temperature manually. Report the alarm at the end of the day.
35RedTake immediate actionCheck the operating relay circuit
36RedTake immediate actionElectric motor did not operate
37Green = OKCheck diesel engine coolant levelReport the alarm at the end of the day.
38RedTake immediate actionReversed electrical phase
39YellowCheck water valve circuitCheck the temperature manually. Report the alarm at the end of the day.
40YellowCheck high-speed circuitIf the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
41YellowCheck diesel engine coolant temperatureReport the alarm at the end of the day.
42YellowUnit forced at low speedReport the alarm at the end of the day.
43Green = OKUnit forced at low modulation speedReport the alarm at the end of the day.
44RedTake immediate actionCheck the fuel system
45YellowCheck hot gas bypass circuitIf the unit or zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
46YellowCheck air flow (zone)Check the temperature manually. Report the alarm at the end of the day.
47RedTake immediate actionRemote sensor shutdown
48RedTake immediate actionCheck belts or clutches associated with the diesel engine.
49Green = OKCheck spare sensor 1Report the alarm at the end of the day.
50Green = OKReset the clockReport the alarm at the end of the day.
51RedTake immediate actionCheck shutdown circuit
52YellowCheck heating circuit (zone)If the unit or zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
53YellowCheck economizer valve circuitIf the unit or zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
54Green = OKTest mode wait timeClear the alarm and restart the unit.
55Green = OKCheck diesel engine speedsOperator action: report the alarm at the end of the day.
56YellowCheck low-speed evaporator fan (zone)Operator action: If the unit or zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
57YellowCheck high-speed evaporator fan (zone)If the unit or zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.

Table 2: Alarms 61-90

Alarm CodeStatusDescriptionAction
61YellowLow battery voltageCheck with a multimeter. If the unit or zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
62RedTake immediate actionAmmeter out of calibration
63RedTake immediate actionEngine or steam engine stopped
64Green = OKPre-trip reminderReport the alarm at the end of the day.
65YellowAbnormal temperature differential (zone)If the unit or zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
66RedTake immediate actionLow diesel engine oil level
67YellowCheck liquid line solenoid circuitIf the unit or zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
68RedTake immediate actionInternal controller fault code
70Green = OKHour counter failureReport the alarm.
71Green = OKHour counter 4 exceeds set time limitReport the alarm at the end of the day.
72Green = OKHour counter 5 exceeds set time limitReport the alarm at the end of the day.
73Green = OKHour counter 6 exceeds set time limitReport the alarm at the end of the day.
74Green = OKController reset to default valuesReport the alarm at the end of the day.
75RedTake immediate actionController

Table 1:

Alarm CodeColorDescriptionAction
61YellowLow battery voltage. Check with a multimeter.If the unit or zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
62RedTake immediate action. Ammeter out of calibration.The unit cannot operate and is turned off. Repair immediately.
63RedTake immediate action. Engine or steam engine stopped.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
64GreenOK. Pre-trip reminder.Report the alarm at the end of the day.
65YellowAbnormal temperature differential (zone).If the unit or zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
66RedTake immediate action. Low diesel engine oil level.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
67YellowCheck the solenoid circuit of the liquid line in the cooling circuit (zone).If the unit or zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
68RedTake immediate action. Internal controller fault code.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
70GreenOK. Hour counter failure.Report the alarm.
71GreenHour counter 4 exceeds the set time limit.Report the alarm at the end of the day.
72GreenHour counter 5 exceeds the set time limit.Report the alarm at the end of the day.
73GreenHour counter 6 exceeds the set time limit.Report the alarm at the end of the day.
74GreenReset the controller to default values.Report the alarm at the end of the day.
75RedTake immediate action. Controller RAM error.Operator action: If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
76RedTake immediate action. Controller EPROM failure.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
77RedTake immediate action. Controller EPROM checksum error.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
78RedTake immediate action. Data register EPROM error.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
79GreenOK. Internal data register overflow.Report the alarm at the end of the day.
80GreenOK. Check the compressor temperature sensor.Operator action: Report the alarm at the end of the day.
81RedTake immediate action. High compressor temperature.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
82RedTake immediate action. Shutdown due to high compressor temperature.The unit cannot operate and is turned off. Repair immediately.
83GreenOK. Low engine coolant temperature.Report the alarm at the end of the day.
84GreenOK. Null reset.Report the alarm at the end of the day.
85GreenOK. Forced unit operation.Operator action: Report the alarm at the end of the day.
86GreenOK. Check the discharge pressure sensor.Report the alarm at the end of the day.
87GreenOK. Check the suction pressure sensor.Report the alarm at the end of the day.
88GreenOK. Reserved for CR.
89GreenOK. Check the electronic expansion valve (ETV) circuit.Operator action: If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
90GreenElectrical overload.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.

Table 2:

Alarm CodeColorDescriptionAction
91GreenOK. Check the electrical input.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
92GreenOK. Sensor degrees not set (zone).Operator action: Report the alarm at the end of the day.
93GreenOK. Low compressor suction pressure.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
94GreenOK. Check charger circuit #1.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
95GreenOK. Check charger circuit #2.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
96YellowLow fuel level.Add fuel as needed.
97RedTake immediate action. Remote air return sensor failed (CR).If the unit or zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
98GreenOK. Check the fuel level sensor.Report the alarm at the end of the day.
99RedTake immediate action. High compressor pressure ratio.Operator action: If the unit/zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
100YellowHeater fan failure (CR).If the unit/zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
100RedTake immediate action. Evaporator coil outlet temperature control (CR).Monitor temperature manually. Report the alarm at the end of the day.
102YellowLow evaporator coil temperature (CR).If the unit/zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
103YellowLow
Alarm CodeStatusDescriptionOperator Action
91Green = OKCheck electrical input ready.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
92Green = OKSensor degrees not set (zone).Operator Action: Report the alarm at the end of the day.
93Green = OKLow compressor suction pressure.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
94Green = OKCheck charger circuit #1.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
95Green = OKCheck charger circuit #2.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
96YellowLow fuel level.Add fuel as needed.
97RedImmediate action required.Failed remote air return sensor (CR).
98Green = OKCheck fuel level sensor.Report the alarm at the end of the day.
99RedImmediate action required.High compressor pressure ratio.
100YellowHeater fan failure (CR).If the unit or zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
100RedImmediate action required.Evaporator coil output temperature control (CR).
102YellowLow evaporator coil temperature (CR).If the unit/zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
103YellowLow heater fuel level (CR).Monitor temperature manually. Report the alarm at the end of the day.
104YellowCheck remote fan speed (zone).Operator Action: Monitor temperature manually. Report the alarm at the end of the day.
105YellowCheck tank receiver sun press circuit.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
106YellowCheck purge valve circuit.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
107YellowCheck condenser sun input circuit.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
108YellowDoor open wait time (zone).Close doors. Report the alarm at the end of the day.
109Check high discharge pressure sensor.Replaced by alarm code 86.
110YellowCheck suction line sun circuit (zone).If the unit/zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
111Green = OKUnit not configured correctly (zone).Operator Action: Report the alarm at the end of the day.
112YellowCheck remote fans (zone).If the unit/zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
113YellowCheck electric heating circuit (zone).Monitor temperature manually. Report the alarm at the end of the day.
114RedImmediate action required.Multiple alarms: cannot run (zone).
115YellowCheck high-pressure cutout switch.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
116Green = OKCheck high-pressure cutout switch.Operator Action: Report the alarm at the end of the day.
117Green = OKAutomatic switch from diesel to electric.Operator Action: Normal operation; does not affect performance.
118Green = OKAutomatic switch from electric to diesel.Normal operation; does not affect performance.
119Reserved for CR.
120YellowCheck alternator excitation circuit.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.

Table 2:

Alarm CodeStatusDescriptionOperator Action
121YellowCheck liquid PMW injection circuit.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
122YellowCheck electrical or diesel circuit.If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
123YellowCheck evaporator coil inlet temperature sensor (CR).Monitor temperature manually. Report the alarm at the end of the day.
124Green = OKCheck evaporator coil outlet temperature sensor (CR).Report the alarm at the end of the day.
125YellowCheck tank level sensor (CR).Operator Action: If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
126YellowCheck back pressure regulator (CR).Monitor temperature manually. Report the alarm at the end of the day.
127YellowSetpoint not entered (zone).Ensure the setpoint is adjusted to the required temperature.
128Green = OKMaintenance reminder #1 engine runtime/service date.Operator Action: Report the alarm at the end of the day.
129Green = OKMaintenance reminder #2 engine runtime.Report the alarm at the end of the day.
130Green = OKMaintenance reminder #1 engine runtime.Report the alarm at the end of the day.
131Green = OKMaintenance reminder #2 electric runtime.Report the alarm at the end of the day.
132Green = OKMaintenance reminder #1 total unit runtime.Operator Action: Report the alarm at the end of the day.
133Green = OKMaintenance reminder #2 total unit runtime.Report the alarm at the end of the day.
134Green = OKController runtime hours

Table 1:

Alarm CodeStatusDescription
121YellowCheck the PMW liquid injection circuit. If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
122YellowCheck the electrical or diesel circuit. If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
123YellowCheck the evaporator coil (CR) inlet temperature sensor. Monitor the temperature manually. Report the alarm at the end of the day.
124GreenOK. Check the evaporator coil (CR) outlet temperature sensor. Report the alarm at the end of the day.
125YellowCheck the tank level sensor (CR). Operator action: If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
126YellowCheck the pressure regulator (CR). Monitor the temperature manually. Report the alarm at the end of the day.
127YellowPoint not set (zone). Ensure the setpoint is adjusted to the required temperature.
128GreenOK. Maintenance reminder #1 for engine runtime/service date. Operator action: Report the alarm at the end of the day.
129GreenOK. Maintenance reminder #2 for engine runtime. Report the alarm at the end of the day.
130GreenOK. Maintenance reminder #1 for engine runtime. Report the alarm at the end of the day.
131GreenOK. Electrical runtime maintenance reminder #2. Report the alarm at the end of the day.
132GreenOK. Maintenance reminder #1 for total unit runtime. Operator action: Report the alarm at the end of the day.
133GreenOK. Maintenance reminder #2 for total unit runtime. Report the alarm at the end of the day.
134GreenOK. Controller operating hours. Operator action: Report the alarm at the end of the day.
135GreenOK. Check spare digital inputs. Report the alarm at the end of the day.
136GreenOK. Check spare digital outputs. Report the alarm at the end of the day.
137YellowCheck the damper motor engine heater output. If the unit/zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
138GreenOK. Real-time clock battery failure (DAS). Report the alarm at the end of the day.
139GreenOK. Abort evacuation mode. Report the alarm at the end of the day.
140Unused

Table 2:

Alarm CodeStatusDescription
141YellowAuto Switch Diesel to Electric Disabled. Report the alarm at the end of the day.
142YellowCheck the Thermax valve. If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
143GreenOK. Check the remote drain hose heater output (zone). Report the alarm at the end of the day.
144RedTake immediate action. CAN communication lost to expansion module. The unit cannot operate and is off. Repair immediately.
145YellowLost ON feedback signal from the controller. If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
146GreenOK. Software version mismatch. Report the alarm at the end of the day.
147YellowCheck the multiple temperature fan speed control output (zone). Monitor the temperature manually. Report the alarm at the end of the day.
148YellowElectric to diesel automatic switch disabled. Report the alarm at the end of the day.
149YellowUnidentified alarm. If the unit/zone shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
150GreenOK. Low-range sensor (DAS and HMI) (zone). Report the alarm at the end of the day.
151GreenOK. High-range sensor (DAS and HMI) (zone). Report the alarm at the end of the day.
152GreenOK. Failed DAS sensor (DAS). Report the alarm at the end of the day.
153GreenOK. Failed DAS sensor (DAS). Report the alarm at the end of the day.
154YellowLow suction pressure switch failure. If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
155RedTake immediate action. CAN communication lost to HMI. The unit cannot operate and is off. Repair immediately.
156YellowCheck the liquid or suction heat exchanger bypass valve. If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
157GreenOK. OptiSet Plus profile discrepancy. Report the alarm at the end of the day.
158GreenOK. Main software loading error. Report the alarm at the end of the day.
159GreenOK. Check battery status. Report the alarm at the end of the day.
160GreenOK. CAN communication lost to radio expansion board. Report the alarm at the end of the day.
161GreenOK. Invalid DAS real-time clock record (DAS). Report the alarm at the end of the day.
163YellowEmission control failure. If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
175YellowCheck the electronic expansion valve (CR). If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
176YellowCheck the evaporator pressure sensor (CR). If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
177YellowCheck the CO2 tank pressure sensor (CR). If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
178YellowLow CO2 fuel level (CR). If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
180YellowCompressor TriPac Alarm. If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.

Table 1:

Alarm Code 151Status: GreenSensor out of high range (DAS and HMI) (zone)Report the alarm at the end of the day.
Alarm Code 152Status: GreenFailed DAS sensor (DAS)Report the alarm at the end of the day.
Alarm Code 153Status: GreenFailed DAS sensor (DAS)Report the alarm at the end of the day.
Alarm Code 154Status: YellowLow suction pressure switch failureIf the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
Alarm Code 155Status: RedTake immediate actionDescription: CAN communications lost to HMI
Alarm Code 156Status: YellowCheck liquid or suction heat exchanger valveIf the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
Alarm Code 157Status: GreenOptiSet Plus profile discrepancyReport the alarm at the end of the day.
Alarm Code 158Status: GreenMain software loading errorReport the alarm at the end of the day.
Alarm Code 159Status: GreenCheck battery statusReport the alarm at the end of the day.
Alarm Code 160Status: GreenCAN communications lost to radio expansion boardReport the alarm at the end of the day.
Alarm Code 161Status: GreenInvalid DAS real-time clock (DAS)Report the alarm at the end of the day.
Alarm Code 163Status: YellowEmission control failureIf the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
Alarm Code 175Status: YellowCheck electronic expansion valve (CR)If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
Alarm Code 176Status: YellowCheck evaporator pressure sensor (CR)If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
Alarm Code 177Status: YellowCheck CO2 tank pressure sensor (CR)If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
Alarm Code 178Status: YellowLow CO2 fuel level (CR)If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
Alarm Code 180Status: YellowCompressor TriPac alarmIf the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.

Table 2:

Alarm Code 188Status: YellowDAS microprocessor error reportReport the alarm at the end of the day.
Alarm Code 203Status: YellowCheck screen return air sensor (zone)Monitor temperature manually. Report the alarm at the end of the day.
Alarm Code 204Status: YellowCheck screen discharge air sensor (zone)Monitor temperature manually. Report the alarm at the end of the day.
Alarm Code 216Status: GreenCheck DAS digital inputs (DAS)Report the alarm at the end of the day.
Alarm Code 233Status: GreenOK to run, REB off, total conservativeReport the alarm at the end of the day.
Alarm Code 234Status: GreenCheck relative humidity sensor circuitReport the alarm at the end of the day.
Alarm Code 235Status: GreenHigh engine coolant temperature reviewReport the alarm at the end of the day.
Alarm Code 250Status: GreenReset DAS clockReport the alarm at the end of the day.
Alarm Code 251Status: GreenCheck radio expansion board settingsReport the alarm at the end of the day.
Alarm Code 252Status: GreenCheck automatic fresh air exchange circuitReport the alarm at the end of the day.
Alarm Code 253Status: GreenREB with backup battery, alarms disabledReport the alarm at the end of the day.
Alarm Code 254Status: GreenCheck auxiliary coolant temperature sensorReport the alarm at the end of the day.
Alarm Code 500Status: YellowCheck host evaporator fan low speedNot implemented
Alarm Code 501Status: YellowCheck host evaporator fan high speedNot implemented
Alarm Code 505Status: YellowCheck road condenser fan motor speed circuitIf the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
Alarm Code 506Status: YellowCheck curb condenser fan motor speed circuitIf the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
Alarm Code 507Status: GreenCheck digital displacement output circuit (displacement only)If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
Alarm Code 508Status: GreenOK to run, speed request communication errorReport the alarm at the end of the day.
Alarm Code 509Status: YellowECU failed to enableIf the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
Alarm Code 510Status: YellowECU run signal failedIf the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
Alarm Code 511Status: GreenEngine start waiting time exceededReport the alarm at the end of the day.
Alarm Code 512Status: YellowCompressor suction high pressure (displacement only)If the unit shuts down, repair immediately. Otherwise, report the alarm at the end of the day.
Alarm Code 513Status